Construction method(frp) - List of Manufacturers, Suppliers, Companies and Products

Construction method Product List

1~8 item / All 8 items

Displayed results

Water Treatment Facility (Wastewater Treatment Tank) Jickboard T Method

Introduction to the sheet lining method with high durability, which allows for easy construction and shortened construction periods.

This technology is a corrosion protection method for the inner surface of tanks that can be applied on wet surfaces or in high humidity conditions. After applying a special mortar to the concrete structure or after section repair, a jig board is pressed onto it immediately after application, achieving full adhesion with the concrete structure. This method eliminates the need for support materials, allowing for a shortened construction period. Additionally, FRP molded products are installed with a corrosion-resistant sealing material to create a double structure, providing high durability that prevents damage to the joint areas. 【Features】 ■ Can be applied on wet surfaces or in high humidity ■ Easy application reduces construction time ■ No need for support materials ■ The special mortar for adhesion can bond to wet surfaces of the concrete substrate *For more details, please refer to the PDF document or feel free to contact us.

  • Renovation and repair methods

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Water supply facility corrosion prevention and waterproofing (soft polyester resin) Zick Aqua 149 method

FRP lining method for the inner surface of concrete water tanks for water supply.

▼Overview The Zik Aqua 149 method meets the Japan Water Works Association (JWWA) K149 standards and is a lining method for concrete water tanks using a composite of soft polyester resin and corrosion-resistant polyester resin. ▼Features - It meets the water quality standards related to water supply facilities as stipulated by the Ministry of Health, Labour and Welfare, as well as the JWWA K149 standards, making it applicable to the inner surfaces of concrete water tanks in water supply facilities. - It is an FRP lining method reinforced with glass fibers using soft polyester resin, combining flexibility and high strength, while demonstrating corrosion resistance and waterproofing. - Its high strength and flexibility enhance crack-following capability. - It has excellent weather resistance.

  • Water Supply Facilities

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Coating-type lining method (reinforcement material mixing specification) Gikutecht VE method

High durability chemical-resistant non-matte FRP lining

A type of coating lining method. The Ziktect VE method is a vinyl ester resin coating lining method that does not require the impregnation and degassing process of glass mats found in conventional FRP corrosion protection methods. The vinyl ester resin, which is blended with special glass short fiber reinforcement materials, can form a corrosion-resistant coating layer using common painting tools such as rollers, trowels, and brushes. The formed corrosion-resistant coating layer excels not only in sulfuric acid resistance and alkali resistance required in sewage environments but also in chemical resistance. This method can meet quality standards A to D for coating lining methods used in sewage systems.

  • Sewerage facilities

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Anti-corrosion coating and sheet lining method (prepreg post-application type) HKS method

Dramatically improve the quality of the sheet joint area.

▼Overview The HKS method is a corrosion protection coating technique applied to concrete exposed to harsh corrosive environments. In traditional post-laminated sheet lining methods using prepreg, the seams become laps, raising concerns that ultraviolet light may not adequately penetrate, resulting in incomplete curing. The seam treatment in the HKS method employs a revolutionary corrosion protection coating technique that uses molded joint materials made of high corrosion-resistant vinyl ester resin FRP for joint treatment. ▼Features This method involves applying HKS sheets to concrete surfaces or cross-section repair surfaces that have been coated with primer, followed by ultraviolet irradiation to achieve complete curing and integration with the concrete. The joints feature a double structure where FRP molded products are installed with a highly corrosion-resistant sealing material, providing excellent durability. Compared to traditional post-laminated sheet lining methods that involve overlapping sheets for joint treatment, this method offers superior workability. Additionally, it possesses sufficient corrosion resistance for the harsh corrosive environments found in sewer-related facilities.

  • Sewerage facilities

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Anti-corrosion coating and sheet lining method D type, Zickboard T method

Can be applied in wet surfaces and high humidity, easy to install, reducing construction time.

▼Overview The Zickboard T method involves applying an inorganic mortar to a concrete structure or after cross-section repair, and immediately pressing the Zickboard onto it to achieve full adhesion with the concrete structure. This method eliminates the need for support materials and allows for a shortened construction period. ▼Features - The joints of the Zickboard T method are constructed with FRP molded products installed with a corrosion-resistant sealing material, creating a double structure that provides durability to prevent damage at the joint areas. - The inorganic mortar used for adhering the Zickboard can bond to wet surfaces of the concrete substrate, making it suitable for construction in high humidity environments.

  • Sewerage facilities

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Anti-corrosion coating and sheet lining method D type, Zickboard S method.

Coating-type lining method + sheet lining method leads corrosion protection into a new era.

▼Overview The Zick Board S method involves applying a surface preparation material (Zick Resin HE104X) to the concrete structure, followed by the application of an odor-reducing epoxy resin (Zick Light E310 or Zick Light E410) to both the surface preparation area and the back of the Zick Board. The Zick Board is then adhered to the concrete structure immediately after application, creating a full adhesion. ▼Features - The joints of the Zick Board S method are designed with FRP molded products installed with a corrosion-resistant sealing material, creating a double structure that provides durability and prevents damage to the joint area. - As a hybrid structure that fully adheres the sheet lining method using a coating type lining method, it eliminates the need for support materials, allowing for a reduction in construction time.

  • Sewerage facilities

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Anti-corrosion coating and sheet lining method D type, Zicboard GR method.

Reduction of life cycle costs with a durability of 50 years.

▼Overview The Zick Board GR method has a construction track record of over 20 years, and based on follow-up survey results of operational facilities and promotion test results, it has been verified that even 50 years after completion, it can maintain the performance of "adhesion stability," "sulfuric acid resistance," and "barrier properties," ensuring a service life of 50 years. By having a service life of 50 years, it enables a reduction in lifecycle costs compared to coating-type lining methods and other sheet lining methods. ▼Features - The joints of the Zick Board GR method have a triple structure consisting of FRP molded products on the surface and back, along with corrosion-resistant sealing materials, providing excellent durability functions that prevent damage to the joint area due to stress concentration and other factors. - The Zick grout injected into the back of the Zick Board can also serve as a cross-section restoration process after the removal of deteriorated areas during renovation work.

  • Sewerage facilities

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Anti-corrosion coating and sheet lining method D type, Jickboard K method

Since the sheet adhesion is completed during the formwork removal, it is possible to shorten the construction period.

▼Overview The Zickboard K method involves attaching 2mm Zickboard to the formwork during the construction of treatment facilities and directly adhering it to the concrete structure. Since the application of the Zickboard is completed when the formwork is removed, this method allows for a significant reduction in construction time compared to other sheet lining methods. ▼Features - Zickboard has good workability and can be cut to match the shape of the formwork. It can also be installed using plastic nails or similar fasteners. - The joints and separator ends of the Zickboard K method are equipped with FRP molded panels and corrosion-resistant sealants, providing durability features that prevent damage to the joints. ▼Method Standards Complies with the quality standards of the Japan Sewage Works Agency's "Manual for Corrosion Control and Anti-Corrosion Technology for Concrete Structures in Sewage Systems," specifically the D-type formwork sheet lining method.

  • Sewerage facilities

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration